W A R M I N G
TECHNOLOGIES
IvNow individual warming pods
The ivNow® fluid warmer quickly warms and maintains the temperature of injection/intravenous and irrigation solutions prior to their use. The specially contoured warming module cradles solution bags in 0.5-, 1-, 2-& 3-liter sizes. ivNow® units can be customized in the field by stacking or removing pods from the configuration. Units can be used for counter top use or wall mounted with the provided mounting plate. The units are controlled individually with electronic controls with an L.E.D. display for each cavity. The control can easily be set to display temperatures in Celsius or Fahrenheit. A sensor in the heating plate detects the presence of a bag and engages the heating mechanism to quickly begin warming the fluid. Two (2) temperature sensors work in unison to precisely and continuously read the temperature of the bag and another sensor monitors the plate temperature. A green ready light will illuminate when fluid is within +0/-2°C (+0/-3ºF) of the set point temperature. The heater will reengage as necessary to maintain the temperature within +0/-2°C (+0/-3ºF) of the set point. The electronic control monitors the length of time the bag has been held at temperature, beginning when the bag reaches set point temperature. A status button will display the time the fluid has been held at temperature. Each ivNow® internally tracks the duration an IV bag has been held at the desired temperature. Time duration can be retrieved using the STATUS button. When the IV bag has been warmed longer than 14 days (user adjustable from 7 to 60 days), ivNow® will flash DATE on the LED screen to inform clinician the limit has been exceeded and the bag should be discarded.
Modular Configuration Wall mount: One to six (1-3) bag capacity Counter top: One to three (1-3) bag capacity Pole mount: One to three (1-3) bag capacity Warranty 1 year parts and labor Temperature: Heats to 104°F (40°C) in 30 minutes or less (slightly longer heating time is required for 3L bags) Accuracy of +0°/-2°C (+0°/-3°F)
Medical Grade Plastic Housing
Status Button
Power
Status Indicator Light
Display
Electronic Control Monitors the length of time the bag has been held at temperature, displayed additionally by a status button. The control alerts users when a fluid bag has been held at temperature longer than 14 days.
#P-2301-A IVNOW-1 CAPACITY ONE (1) BAG, #P-2302-A IVNOW-2 CAPACITY TWO (2) BAGS #P-2303-A IVNOW-3 CAPACITY THREE (3) BAGS
42
Associated Health Systems Inc.
info@ahsinc.ca
877.457.8012
www.ahsinc.ca
Powered by FlippingBook